How do I pair my wireless remote control with the receiver?
1. Set the engine switch to the ON position (middle position).
2. Turn on the battery switch.
3. Press and hold the programming button on the left-hand side of the control panel, next to the red light, for approximately three seconds until the light comes on.
4. Briefly press the STOP button on the remote control. The red LED will flash once to clear the remote programming. If you have a second remote control, press its STOP button as well.
5. Briefly press and release the START button. The red LED will flash once to programme the remote control. If you have an additional remote control, press its START button as well.
6. Press and hold the programming button for approximately three seconds until the red light goes out.
What size generator do I need to run a welder?
A welder is rated by its output current. To estimate the input power, divide the output rating by 30.
Example calculation:
A 130 A welder requires an input power of 130/30 = 4.3 kW.
A 200 A welder requires an input power of 200/30 = 6.7 kW.
However, this is only a rough estimate, so it is always advisable to choose a generator one size larger. Bear in mind that you will rarely need the full capacity of your welder. A smaller generator would still operate the welder, but would limit the welding current.
What size generator do I need to start a motor?
There are many different types of motors with different characteristics. Some motors, such as induction motors (capacitor-start / capacitor-run), require additional starting current, which means a larger generator is needed. Motors used in tools generally do not require additional starting current. It is therefore advisable to ask the manufacturer whether the equipment in question requires additional starting current.
As a rough guide, a generator should be rated at 2.5 to 3 times the motor's power. Motors may be rated in kW or horsepower. To convert horsepower to kW, multiply the value by ¾.
Example calculation:
What generator is needed to run a 3 hp motor? 3 hp = 3 x ¾ = 2.25 kW. This induction motor would therefore require a generator rated between (2 ½ x 2.25) = 5.625 kW and (3 x 2.25) = 6.75 kW.
What are kW and kVA? What is the power factor?
There are three basic types of power:
1) Active power, measured in watts (W).
This is the power drawn by a resistive load, such as the heating element in a kettle, and has a power factor of 1. (Unity power factor, cos F = 1, 1.0 pf or pf = 1.)
2) Reactive power, measured in volt-amperes reactive (VAr).
This is the power drawn by a reactive load (a load with a winding around a core), such as an electromagnet, and has a power factor of 0. (Zero power factor, cos F = 0, 0 pf or pf = 0.)
3) Apparent power, measured in volt-amperes (VA).
Many loads combine resistive and reactive elements. In fact, it is not possible to create a purely inductive load, because the wire used to form the windings has resistance. This combination of elements means that both active power (W) and reactive power (VAr) are combined.
The ratio of active power to reactive power is defined as the power factor. Almost all resistive loads, such as universal motors in power tools, have a power factor of 0.95 to 1.0. Almost all inductive loads have a power factor of approximately 0.3. The vast majority of single-phase loads have power factors close to 1.
Single-phase generators are therefore rated at a power factor of 1 and are consequently specified in watts (W) or kilowatts (kW). Accordingly, 1 kW = 1000 W.
Three-phase loads tend to have lower power factors, around 0.8. Three-phase generator ratings are therefore calculated at a power factor of 0.8 and specified in VA or kVA.
There is a relationship between active power, reactive power, apparent power and power factor:
i) Apparent power (VA) = √[(Active power (W))² + (Reactive power (VAr))²], and
ii) Power factor = Active power (W) / Apparent power (VA)
Therefore: Apparent power (VA) x Power factor = Active power (W)
If the power factor is 1, all the power is active power, and apparent power (VA) = active power (W). (W = VA at 1.0 pf.)
A single-phase generator should be rated at 1.0 pf, where watts equal volt-amperes. A three-phase generator, however, is rated at 0.8 pf.
This is where confusion can arise!
Example:
A three-phase generator has a continuous rating of 5 kVA at 0.8 pf. At this rated load, the active power (kW) is:
Active power (kW) = Apparent power (kVA) x Power factor. Active power = 5 x 0.8 = 4 kW.
This means that a generator rated at 5 kVA with a power factor of 0.8 actually produces 4 kW of active power, while also producing reactive power.
From i): 5000 VA = √[(4000 W)² + (Reactive power)²]. Reactive power = 3000 VAr.
It is this combination of 4 kW of active power and 3 kVAr of reactive power that defines the upper limit of the generator's output. If the same generator were supplying only a resistive load, it might be able to provide more than 4 kW, but there is no formula for determining this limit from the 0.8 pf rating. It can only be established by testing each individual load. Similarly, a 4 kW single-phase generator cannot produce 5 kVA at 0.8 pf.
What is the difference between three-phase and single-phase generators?
To illustrate the difference between single-phase and three-phase power, imagine a person paddling a canoe. This person can only propel it forwards while the paddle moves through the water. When the paddle leaves the water in preparation for the next stroke, the energy supplied to the canoe is zero.
Now imagine the same canoe with three people paddling. If their strokes are synchronised so that each is separated by one-third of a stroke cycle, the canoe receives constant, even propulsion through the water. More power is delivered, and the canoe moves more smoothly and efficiently.
How do single-phase and three-phase systems work?
Single-phase systems use alternating current, in which the voltage and current change cyclically in magnitude and direction, typically 60 times per second. In the USA, the single-phase voltage is 120 volts, while 230 volts is the predominant standard in Europe.
In three-phase systems, the power circuit combines three alternating currents that are 120 degrees apart in phase. As a result, the power can never fall to zero, allowing a greater load to be supplied. In a typical 120-volt arrangement, this corresponds to three 120-volt single-phase circuits and one 208-volt circuit.
What are the advantages of three-phase systems over single-phase systems?
The installation and maintenance costs of three-phase systems are significantly lower than those of single-phase systems. Three-phase systems use considerably less conductor material, approximately 25 per cent less for the same amount of power. Over the same period, three-phase power lines can carry more energy than single-phase lines, at a lower cost. In addition to using less copper, a three-phase system requires fewer circuit breakers for 208-volt loads. The power delivered in three-phase circuits is almost constant, making them ideal for transmission lines, power grids and data centres.
Three-phase generators draw significantly fewer amps than single-phase generators because they use a coefficient of 1.733. The three-phase equation is: Watts (W) / Voltage (V) / Coefficient (1.733) = Amps (A).
Due to the alternator's wiring configuration, dual-voltage generators only produce their full output at the higher voltage. Single-phase or lower-voltage output uses only two of the alternator's four windings, typically resulting in a 40–50% reduction from the stated continuous output. If a generator offers both three-phase and single-phase output, the maximum rating always applies to the higher voltage, for example 415 V. In this case, the single-phase output is 40–50% lower.
Can I run sensitive equipment such as my computer on a generator?
The power supplied by the mains in your home and the power supplied by a generator are not identical. Generator output is less stable.
Engine speed depends on the load. The speed decreases as the load increases. The frequency of the output voltage depends directly on engine speed, so it changes with the load. The output voltage also varies with load and temperature.
The output voltage of most standard generators stays within 230 V +/- 10%, from no load up to the rated load current specified on the nameplate. This is the voltage range guaranteed by electricity network operators. The output frequency usually varies between 53 Hz at no load and 49 Hz at rated load current, while the mains frequency generally never varies by more than 0.1 Hz.
Most electronic devices are designed to handle these fluctuations. Nevertheless, we recommend asking the manufacturer whether the equipment can be operated reliably with a portable generator.
When fuel runs low, the engine may run unevenly, which can cause voltage spikes. An uninterruptible power supply (UPS), sometimes referred to as a battery backup, can be used to prevent a direct impact on your electronic equipment. This prevents sensitive data from being lost in the event of a power failure.
Inverter technology for stable power
Computers and power-sensitive test equipment require a constant voltage and a stable sine wave. Ordinary loads, such as lights and other household appliances, can tolerate fluctuations in AC power without difficulty.
However, if you run sensitive electronic equipment, such as your computer, on a generator and the voltage fluctuates, there is a risk of the computer shutting down or the power supply being interrupted. A revolutionary form of inverter technology was developed to overcome this problem. It produces a pure sine wave that is as good as, or better than, the electricity from your household socket.
This means that you can run a computer or laptop directly from an inverter generator.
What is AVR?
AVR is generally comparable to an inverter generator. Generators equipped with AVR (Automatic Voltage Regulator) limit voltage fluctuations to +2%/-2%. An AVR-equipped generator can therefore also be used to run sensitive devices such as computers.
Can I connect my own residual current device?
A generator is configured differently from the mains supply. The generator has a floating earth arrangement, whereas the mains supply has an earthed neutral.
Although it is recommended to use a separate residual current device (RCD) with the mains supply in most applications, this is not necessary with a generator. Generators operate reliably and safely without a residual current device. Separate RCDs are designed to trip when used with a mains supply.
If you want to use a separate RCD with a generator, the generator must be configured in the same way as the mains supply. This is a relatively simple modification for a qualified electrician, involving a link from the neutral terminal to the earth terminal. Once the generator has been modified, however, a separate RCD and an earth rod connecting the generator frame to the ground must always be used. As this can be difficult to implement, it is advisable not to modify the generator.
If you are still unsure which generator you need, please contact us by phone or email:
Tel: +49(0)8234/7066240
What do I need to know about noise emissions?
The decibel, commonly abbreviated as dB(A), is the unit used to measure sound intensity. The human ear is incredibly sensitive. It can perceive extremely quiet sounds as well as very loud ones. To illustrate this, a jet aircraft is up to 1,000,000,000,000 (one trillion) times louder than the quietest audible sound.
On the decibel scale, the quietest audible sound is close to 0 dB. An increase of 10 decibels corresponds to a tenfold increase in the sound intensity reaching your ear.
IMPORTANT: “Generator noise levels are usually measured at a distance of approximately 7 metres.”
To comply with EEC regulations, all generators must be labelled with their LWA value, a measure of the total sound power emitted by a device in all directions. This is a different measurement method taken at a different distance. For example, a generator rated at 52 dB(A) at 7 metres corresponds to approximately 88 decibels on the LWA scale. Please pay attention to which values are specified.
Here is an overview of various sound sources and their corresponding noise levels in decibels:
120 Pneumatic drill
110 Noisy factory
100 Inside an underground train
90 Inside a bus
80 Average traffic on a main road (measured from the kerb)
70 Normal conversation (at 1 m)
60 Typical office
50 Living room in a suburban home
40 Library
30 Bedroom at night
20 Sound-isolated broadcasting studio
10 Threshold of hearing
0 dB Silence
NOTE: An increase of 10 dB corresponds to a doubling of perceived loudness.
Further noise level examples
Additional sound information
190 dB(A) Heavy weapons, 10 m behind the weapon (peak level)
180 dB(A) Toy gun fired next to the ear (peak level)
170 dB(A) A blow to the ear, a firework exploding at shoulder level, small arms at a distance of 50 cm (peak level)
160 dB(A) A hammer striking a brass tube or steel sheet at 1 m, airbag deployment at 30 cm (peak level)
150 dB(A) A hammer blow in a forge at 5 m (peak level)
130 dB(A) Loud handclapping at 1 m (peak level)
120 dB(A) Whistling at 1 m, a jet engine test run at 15 m
Threshold of pain: above this level, even brief exposure may quickly cause hearing damage.
115 dB(A) Aircraft take-off noise at 10 m
110 dB(A) A siren at 10 m, typical sound levels in nightclubs and close to speakers at rock concerts, a violin close to an orchestral musician's ear (peak level)
105 dB(A) A chainsaw at 1 m, a car door slamming at 1 m (peak level), a racing car at 40 m, music through headphones
100 dB(A) Very loud music through headphones, a pneumatic hammer at 10 m
95 dB(A) Loud shouting, a handheld circular saw at 1 m
90 dB(A) Petrol lawnmower
85 dB(A) A two-stroke chainsaw at 10 m, a toilet flushing at 1 m
80 dB(A) Very loud traffic noise from a passing lorry at 7.5 m, frequent motorway traffic at 25 m
75 dB(A) A passing car at 7.5 m, a wood chipper at 10 m
70 dB(A) Noise near a main road during the day, a quiet hairdryer 1 m from the ear
65 dB(A) Normal conversation
60 dB(A)
55 dB(A) A radio or television at low volume at 1 m, a vacuum cleaner at 10 m
50 dB(A) A refrigerator at 1 m, birdsong outdoors at 15 m
45 dB(A) Normal ambient noise; speech or a radio in the background
35 dB(A) A very quiet room, ventilation running at low speed at 1 m
25 dB(A) Breathing sounds at 1 m
0 dB(A) Threshold of hearing
How do I connect my generator to my home during a power cut?
Please observe the following precautions:
It is IMPORTANT that the generator operates completely isolated from the mains supply.
This ensures that the generator does not try to supply electricity to the neighbourhood and that an electrician carrying out maintenance on the electricity supply does not receive an electric shock. A double-pole, break-before-make changeover switch must be installed by an electrician between the electricity meter and the relevant consumer unit. The switch connects the building either to the mains or to a cable that can be connected to the generator.
Configuring the generator to use a residual current device (RCD):
Most buildings already have an RCD integrated into the consumer unit. It is configured for a mains supply with an earthed neutral, rather than a generator with a floating earth arrangement. To use this protective device, the generator must be configured in the same way as the mains supply. This is a straightforward modification for a qualified electrician: fitting a link from the neutral terminal to the earth terminal. It is recommended that this connection be incorporated into the plug connected to the generator. This ensures that the generator remains unmodified and safe when disconnected from the house.
The plug should be labelled as follows:
“Do not connect to the mains: neutral-to-earth bond fitted!”
The cable between the generator and the transfer switch is not protected by the RCD. It is therefore advisable to use steel-armoured cable for this connection.
A local, low-resistance earth rod must be installed.
How do I choose the right generator?
In today's world of consumer choice, the range of many types of equipment, including generators, seems endless. When you buy a genuine Champion generator, you can trust that all our generators meet European standards for safety and reliability. These are premium-quality branded products!
The following questions will help you choose your generator:
How powerful does my generator need to be?
Most appliances have a nameplate with information about their power consumption. The main distinction is between:
• Resistive loads
• Inductive loads
Resistive appliances / resistive loads:
Here, apparent power always equals active power because reactive power is zero, regardless of whether AC or DC is used. The rating on the nameplate is therefore the power required to start and run the device (starting current = running current).
Examples include traditional incandescent bulbs, hotplates and electric heaters. The CHAMPION 1000-watt inverter generator WW71001i-EU is therefore fully sufficient for an 800-watt electric heater, as this appliance only ever requires 800 watts.
Inductive appliances / inductive loads:
Inductive appliances driven by an electric motor behave differently. During start-up, they briefly require several times their stated power, sometimes two to six times the rated output.
Examples include chest freezers, drills, air conditioners and compressors. A 700-watt air conditioner with three times the running current at start-up needs 2100 watts to start. In this case, the appropriate unit to meet this demand would be the CHAMPION 2300-watt inverter generator WW72301i-EU.
If you are unsure about your equipment's actual power consumption, it is always advisable to contact the manufacturer's sales or technical support team. Quote your model number and ask for the starting and running power requirements. With this information, you can easily determine the required size of your generator.
Alternatively, page 19 of the current CHAMPION catalogue provides an overview of approximate power requirements for common appliances.
Do I need a generator with a large fuel tank?
A standard tank on an inverter generator provides approximately 2–4 hours of continuous operation at full load, while open-frame generators typically run for around 4–8 hours. Some long-run generators can even operate overnight. Alternatively, the generator can be supplied with fuel from an additional external tank.
Can I run sensitive equipment such as my computer on a generator?
Running a computer on a standard generator is not advisable. Instead, you need an inverter generator that uses AVR technology (Automatic Voltage Regulation and true sine wave technology). This ensures a stable power supply.
PLEASE NOTE:
When fuel runs low, the engine may run unevenly and stop. An uninterruptible power supply (UPS), sometimes referred to as a battery backup, can be used to prevent a direct impact on your electronic equipment. This prevents sensitive data from being lost in the event of a power failure.
Single-phase or three-phase?
Generators are available in different configurations:
Single-phase, three-phase or both. Single-phase generators come in a wide variety of shapes and sizes and can run on petrol, gas or diesel. Three-phase generators are predominantly diesel models. The model you need depends on your application.
Power outputs and socket connections
If you are looking for a power factor of 1:1, you need a generator with a single-phase output.
If you require a dual-voltage generator, full power will be available at one voltage, while the other will be limited to approximately 40–50% less output. For example, a 415 V / 230 V generator supplies full power at 415 V, but correspondingly less power at 230 V.
Different socket types are available, such as 13 A, 16 A and 32 A, depending on the type and power required.
Still unsure which generator is right for you?
We are happy to help!
Simply contact us at info@championpowerequipment.de or send us a message using the contact form:
Which oil should I use for my generator?
For use in spring, summer and autumn, we recommend CHAMPION 10W30 for both petrol and diesel generators. If this is unavailable, you can also use 10W40.
If you or your customer intend to operate the generator at very low temperatures, usually during the winter months, we recommend 5W30.